Industries

Agriculture Chemical Construction Yes Food and Beverage Hire Yes Manufacturing Mining Oil and Gas Power Generation Yes Pulp and Paper Yes Water and Waste

B Series

Features

  • Non-clog impeller
    The pump incorporates a channel type impeller having a wide channel extending from inlet to exit, preventing internal clogging.

  • OIL LIFTER (patent pending)
    The OIL LIFTER stabilizes the function of the mechanical seal. It increases the life expectancy of the seal and extends the maintenance cycle. The OIL LIFTER is supplied on all pumps of 1.5kW or over.

  • Dual inside mechanical seal
    The pump is furnished with a dual inside mechanical seal located completely in an oil chamber. This seal system does not rely on the pumped media for the lubrication and cooling, which increases the reliability of the sealing.

  • Anti-wicking cable entry
    Every cabtyre cable has an anti-wicking block at the cable entry section of the pump. This unique feature protects the motor from the ingress of water that may be caused by damage to the sheath of the cable. Each pump up to 3.7kW has a rubber moulded cable entry, pumps of 5.5kW or above has en epoxy-filled cable entry.

  • Motor protection device
    Every pump has a motor protection device built in its motor. A circle thermal protector (CTP) is supplied on the pumps up to 7.5kW and miniature thermal protectors (MTP) is supplied on pumps greater than 11kW.

  • Guide rail fitting version
    Guide rail fittings readily connect/disconnectthe pump to/from the piping system only by lifting up and down the pump, allowing easy maintenance and inspection without the need to enter the sump. Pumps in this version have a \"TOS\" identifier on top of their model codes.

  • Automatic type available
    An automatic or auto-alternation version in pumps up to 3.7kW modules. Automatic or auto-alternating B series pumps come with an integrated control circuit and two low voltage float switches. Auto-alternating pumps are used for dual automatic operations without the need of a control panel.

  • Large Pump Range

Large number of pumps for all flow types can be used in applications from 5L/sec (50mm pump) to in excess of 1700L/sec (800mm pump) for standard pumps.

  • Special Options

Galvanic Corrosion Protection

In sea water applications, Tsurumi can supply pumps with higher electrical potential sacrificial anodes so that these parts corrode before the pump material resulting in longer life span for the pump.

High Temperature Liquid

Standard pumps are designed for continuous running at a maximum temperature of 40°C. Two high temperature operating models are available. Rank 60 for operation in liquids up to 60°C and Rank 90 for operation in liquids up to 90°C.

Different Materials

Impellers, pump castings and suction covers can be made of stainless steel, chromium iron and bronze if required.

Applications


  • Transfer of sewage and wastewater at sewage treatment plants
  • Transfer of wastewater at industrial wastewater treatment plants
  • Pumping or boosting sewage and rain water in a sewage lift station
  • Drainage of storm water in a flood control pump station or detention facilities
  • Drainage of sewage and wastewater in factories and buildings
  • Drainage ofrainwater from basements, underground car parks, or underpasses

Performance Curves

Technical Specifications

Model Curve number Discharge (mm) Power (kW) Voltage (V) Cable (m) Max flow (L/s) Shut-off (m) Weight (kg) Max solid (mm) Rated current A 240V or 415V)
Standard
50B2.75S-51 3 50 0.75 240 10 5.7 14 32 19 6.1
50B2.4-51 1 50 0.4 415 20 4.3 9 25 19 1.1
50B2.75-51 3 50 0.75 415 20 7.1 12 25 20 2
50B2.75H-51 2 50 0.75 415 20 5.7 15.5 24 20 2
80B21.5-51 4 80 1.5 415 20 16.6 16 36 40 3.8
100B42.2-51 5 100 2.2 415 20 24.9 16.6 68 45 5.1
100B43.7-51 6 100 3.7 415 20 33 16.2 84 53 8.2
100B43.7H-51 7 100 3.7 415 20 20 20 81 35 8.2
100B45.5-51 8 100 5.5 415 20 34 26 149 40 12.1
100B47.5-51 9 100 7.5 415 20 37.5 30 162 40 15.7
Automatic
50BA2.75S-51 3 50 0.75 240 10 5.7 14 34 19 6.1
50BA2.75H-51 2 50 0.75 415 20 5.7 15.5 34 20 2
80BA21.5-51 4 80 1.5 415 20 16.6 16 40 40 3.8
100BA42.2-51 5 100 2.2 415 20 24.9 16.6 78 45 5.1
100BA43.7-51 6 100 3.7 415 20 33 16.2 94 53 8.2
Auto-alternation
50BW2.75H-51 2 50 0.75 415 20 5.7 15.5 34 20 2
80BW21.5-51 4 80 1.5 415 20 16.6 16 40 40 3.8
100BW42.2-51 5 100 2.2 415 20 24.9 16.6 78 45 5.1
100BW43.7-51 6 100 3.7 415 20 33 16.2 94 53 8.2

Dimensions

All dimensions are in mm

Model D H A A1 A2 A3 B B1 W1 W2 d D1 D2
Standard
50B2.75S-51 250 523 405 226 125 138 199 140 410 170 50 125 125
50B2.4-51 224 443 347 208 85 120 181 140 340 140 50 112 112
50B2.75-51 250 439 405 226 125 138 199 140 410 170 50 125 125
50B2.75H-51 250 415 405 226 125 138 199 140 385 145 50 125 125
80B21.5-51 250 536 446 267 125 165 234 140 465 190 80 125 125
100B42.2-51 331 616 569 322 154 210 303 - 570 225 100 164 167
100B43.7-51 339 690 575 322 160 210 308 - 645 175 100 164 175
100B43.7H-51 331 666 569 322 154 210 303 - 620 225 100 164 167
100B45.5-51 400 824 687 388 194 260 372 400 700 335 100 197 203
100B47.5-51 400 814 687 388 194 260 372 400 720 335 100 197 203
Automatic
50BA2.75S-51 250 523 405 226 125 138 199 140 410 170 50 125 125
50BA2.75H-51 250 415 405 226 125 138 199 140 385 145 50 125 125
80BA21.5-51 250 536 446 267 125 165 234 140 465 190 80 125 125
100BA42.2-51 331 616 569 322 154 210 303 - 570 225 100 164 167
100BA43.7-51 339 690 575 322 160 210 308 - 645 175 100 164 175
Auto-alternation
50BW2.75H-51 250 415 405 226 125 138 199 140 385 145 50 125 125
80BW21.5-51 250 536 446 267 125 165 234 140 465 190 80 125 125
100BW42.2-51 331 616 569 322 154 210 303 - 570 225 100 164 167
100BW43.7-51 339 690 575 322 160 210 308 - 645 175 100 164 175

B series pumps are available to 110kW Prices for free standing units do not include Discharge Bend sets and stand sets. Prices with guide rail include TOS kit but exclude guide rails.

Product Disclaimer: The product information and specifications on this website should be used as a guide only. The customer is responsible for ensuring the capacity and performance of the goods are sufficient and suitable for the customer's purpose. Malcolm Thompson Pumps takes no responsibility for errors or omissions in product features or specifications.