TRN Series
Features
-
High oxygen transfer
The air drawn into the aerator is mixed with pressurized liquid (generated from impeller movement) and directed to the discharge port via a guide vane. This results in a higher dissolution of oxygen as pressures generated are greater than that produced by water depth.
-
Dual inside mechanical seal
The aerator is furnished with a dual inside mechanical seal located completely in an oil chamber. This seal system does not rely on the liquid for the lubrication and cooling, which increases the reliability of the sealing.
-
Non-pressure shaft sealing
The shaft sealing is so designed that neither submergence nor operating pressure acts on the mechanical seal during its operation. This system makes the shaft seal over a few times as durable as previous systems.
-
OIL LIFTER (patent pending)
The OIL LIFTER stabilizes the function of the mechanical seal. It increases the life expectancy of the seal and extends the maintenance cycle. The OIL LIFTER is supplied on all pumps of 1.5kW or over.
-
Anti-wicking cable entry
Every cabtyre cable has an anti-wicking block at the cable entry section of the aerator. This unique feature protects the motor from the ingress of water that may be caused by damage to the sheath of the cable. Each aerator up to 3.7kW has a rubber molded cable entry, and the pump of 5.5kW or above has en epoxy-filled cable entry.
-
Motor protection device
Every aerator has a motor protection device built in its motor. A circle thermal protector (CTP) is supplied on the aerators up to 7.5kW and miniature thermal protectors are supplied on aerators 11kW and over.
-
Non clog impeller
The design of larger passages between impeller vanes allow for larger solids to be passed. This enables the TRN to operate in situations such as sewage tanks without clogging.
-
Self aspirating design
Air is drawn into the aerator due to the pressure difference between the aerator and the liquid while the impeller is moving. As a result, the equipment aerates without need of a blower. In addition diffuser pipe work is not required.
-
Stirring performance
The upward flow of the liquid leaving the aerator generates convection currents. These currents help agitate the liquid, improving oxygen mixing throughout the tank.
Applications
- Aeration, pre-aeration, and/or mixing in sewage treatment plants
- Aeration, pre-aeration, and/or mixing in industrial wastewater treatment plants
- Mixing of liquid for the prevention of flotation of sedimentation
Performance Curves
Technical Specifications
| Model | Discharge (mm) | Power (kW) | Voltage (V) | Max depth (m) | Air volume at max depth (m3/hr) | No. outlets | Weight (kg) | Rated current A (415V) |
| 32TRN2.75 | 32 | 0.75 | 415 | 3.5 | 7 | 6 | 55 | 1.7 |
| 32TRN21.5 | 32 | 1.5 | 415 | 3.5 | 20 | 6 | 55 | 3.5 |
| 50TRN42.2 | 50 | 2.2 | 415 | 3.6 | 39 | 6 | 140 | 5.3 |
| 50TRN43.7 | 50 | 3.7 | 415 | 4 | 55 | 6 | 150 | 8.6 |
| 50TRN45.5 | 50 | 5.5 | 415 | 4 | 78 | 6 | 170 | 12.1 |
| 80TRN47.5 | 80 | 7.5 | 415 | 4.5 | 124 | 6 | 190 | 15.9 |
| 80TRN412 | 80 | 12 | 415 | 6 | 157 | 6 | 200 | 25.7 |
| 80TRN417 | 80 | 17 | 415 | 6 | 202 | 6 | 220 | 35.2 |
| 100TRN424 | 100 | 24 | 415 | 6 | 388 | 8 | 460 | 48 |
| 150TRN440 | 150 | 40 | 415 | 6 | 528 | 8 | 635 | 83 |
Dimensions
All dimensions in mm
| Model | D | H | A | B | d1 | d2 | L | W |
| 32TRN2.75 | 400 | 473 | 184 | 146 | 32 | 90 | 371 | 81 |
| 32TRN21.5 | 400 | 473 | 184 | 146 | 32 | 90 | 371 | 81 |
| 50TRN42.2 | 700 | 689 | 271 | 226 | 50 | 140 | 660 | 123 |
| 50TRN43.7 | 700 | 694 | 271 | 226 | 50 | 140 | 660 | 123 |
| 50TRN45.5 | 700 | 835 | 271 | 226 | 50 | 140 | 660 | 123 |
| 80TRN47.5 | 700 | 868 | 271 | 246 | 80 | 140 | 660 | 133 |
| 80TRN412 | 700 | 898 | 271 | 246 | 80 | 140 | 660 | 133 |
| 80TRN417 | 700 | 958 | 271 | 246 | 80 | 140 | 660 | 133 |
| 100TRN424 | 1000 | 1254 | 385 | 417 | 100 | - | 980 | 272 |
| 150TRN440 | 1000 | 1407 | 550 | 452 | 150 | - | 980 | 269 |
* Chain length 5m. Other lengths available on request