Aquaplus ES Series
Operating Parameters

Temperature Limits
Mechanical Seals
Pressure Limits
Speed Limits
 
Temperature Limits from -10ºc to +105ºc
Temperature Limits of pumps with standard packed gland is from minus 10ºC to 105ºC.

The maximum temperature of pumps with a water cooled stuffing box is 160ºC. Water cooled stuffing boxes are a standard feature available with any Aquaplus pump unit.

 
Mechanical Seals
The mechanical seals comply to VDMA International Dimension Standards and the maximum temperature depends on seal selection.

The standard mechanical seal fitted is a single spring seal with a ceramic stationary face and a carbon rotating face with Buna N elastomer. The standard seal is suitable for temperatures up to 105ºC.

Other seal components are AISI 304 stainless steel.

Double mechanical seals and other seal configurations with SiC V’s SiC faces and or Viton elastomers are available on request.

 
Pressure Limits to 1600kPa
The maximum operating pressure is 1600kPa and the maximum pressure tested is up to 2100kPa

Some pressure and operating pressures may vary from those stated above, whenever making final selections always check the Aquaplus I O & M technical product manual for confirmation of any questionable areas.

Speed Limits from 960rpm to 3600rpm
Maximum speeds for direct coupled pumps vary between 960 rpm and 3600rpm, depending on pump sizes and method of drive.

Speed limitations for vee belt is a different matter and all selections for VS drive units should refer to the technical manual for final selection.